arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitteruserwarning wechat x-twitterxing youku youtube zoom
Change the country selection to see information on the products, services and contact persons that are relevant for your location.
ELP 100-H080 Illustration similar

ELP 100-H080

Compact linear module

ID 315748

Compact linear module ELP, Size: 100, electrical, Linear direct drive, Backlash-free, pre-loaded roller guides

  • Max. stroke: 80 mm
  • Max. driving force: 104 N
Drive concept Linear direct drive
Max. stroke [mm] 80
Nominal force [N] 104
Max. payload (horizontal) [kg] 6
Max. payload (vertical) [kg] 4
Repeat accuracy [mm] ± 0.01
Dead weight including slide [kg] 6.6
Weight of slide [kg] 1.78
Min. ambient temperature [°C] 5
Max. ambient temperature [°C] 55
IP protection class 20
Cleanroom class ISO 14644-1:2015 5
Noise emission [dB(A)] 68
Clearance N (for moment load) [mm] 179
Length X [mm] 338
Width Y [mm] 97
Height Z [mm] 68.5
Nominal voltage [V] 24
Nominal current [A] 1.6
Max. current [A] 5.9
Controller electronics integrated
Communication interface Digital inputs
Number of digital inputs 2
Rated current logic [A] 0.06
Moment Mx max. [Nm] 83
Moment My max. [Nm] 107
Moment Mz max. [Nm] 107
Force Fy max. [N] 3880
Force Fz max. [N] 3880
Force -Fz max. [N] 3880

General notes about the series

Stroke
is the maximum nominal stroke of the unit. It can be reduced on both sides by end stops.

Repeat accuracy
is defined as a distribution of the end positions for 100 consecutive cycles.

Travel times
are pure movement times of the slide. PLC reaction times are not included and have to be considered when the cycle times are determined.

Payload
is the weight of the total weight which is attached to the cantilever arm. Please consider that service life will shorten if the maximum payload is exceeded. SCHUNK cannot assume any warranty for this.

Layout or control calculation
Verifying the sizing of the selected unit is necessary, since otherwise overloading can result. Please contact us for assistance.

Ambient conditions
The modules are mainly designed for the use in clean ambient conditions. Please note that the life time of the modules can shorten if they are used in harsh ambient conditions, and that SCHUNK cannot assume liability in such cases. Please contact us for assistance.

Housing material
Aluminum alloy, coated

Guidance
Backlash-free, pre-loaded roller guides

Drive
Linear direct drive

Scope of delivery
Accessory pack with centering bushings, assembly instructions

Warranty
24 months

Service life characteristics
on request