FTN-AXIA90 SI-1000-50
ID 1512819
Produits alternatifs :
- Contrôle via: EtherNet
- Plage de mesure Fx, Fy: ± 1000 N
- Plage de mesure Fz: ± 2000 N
- Plage de mesure Mx, My: ± 50 Nm
- Plage de mesure Mz: ± 50 Nm
- Indice de protection IP: 67
Détails techniques
| Contrôle via | EtherNet |
|---|---|
| Matériau du corps | Aluminium |
| Câble codeur | 4 m, connecteur M8 vers connecteur M12 |
| Ligne de commande | Répartiteur Y 4 m, connecteur M12 vers connecteur RJ-45 et alimentation 3 contacts (fils dénudés) |
| Poids [kg] | 0.744 |
| Calibration 1 | SI-1000-50 |
| Plage de mesure Fx, Fy [N] | ± 1000 |
| Plage de mesure Fz [N] | ± 2000 |
| Plage de mesure Mx, My [Nm] | ± 50 |
| Plage de mesure Mz [Nm] | ± 50 |
| Surcharge Fx, Fy [N] | ± 5000 |
| Surcharge Fz [N] | ± 10000 |
| Surcharge Mx, My [Nm] | ± 250 |
| Surcharge Mz [Nm] | ± 250 |
| Fréquence de résonance Fx, Fy, Mz [Hz] | 2300.0 |
| Fréquence de résonance Fz, Mx, My [Hz] | 2900.0 |
| Résolution Fx, Fy [N] | 0.4 |
| Résolution Fz [N] | 0.4 |
| Résolution Mx, My [Nm] | 0.01 |
| Résolution Mz [Nm] | 0.01 |
| Indice de protection IP | 67 |
| Diamètre D [mm] | 89.9 |
| Hauteur Z [mm] | 26.9 |
Dimensions and maximum loads
Dimensions and maximum loads
All forces and torques acting on the sensor must be within the specified measurement range.
Exceeding the measurement range will reduce the maximum number of load cycles and may lead to damage of the sensor. Please contact us if your application exceeds the measurement range.
General notes about the series
Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.
Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.
Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C
evaluation via
EtherCAT, Ethernet, RS-422, RS-485
Warranty
12 months