arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitter userwarning wechat xing youku youtube zoom
Change the country selection to see information on the products, services and contact persons that are relevant for your location.
LOG 60.0-M16x1-M5 Illustration similar

LOG 60.0-M16x1-M5

Internal hole gripper

ID 398960

Internal hole gripper LOG, Size: 60, pneumatic, Mounting threads: M16x1, Air connection thread: M5

  • Max. ambient temperature: 80 °C
Mounting thread A M16x1
Air connection thread B M5
Min. workpiece diameter [mm] 60
Max. workpiece diameter [mm] 66.13
Opening force for Ø Dmin [N] 596.7
Opening force for Ø Dmax [N] 190.5
Weight [kg] 0.108
Recommended workpiece weight [kg] 3.04
Fluid consumption double stroke [cm³] 28.82
Max. operating pressure [bar] 6
Nominal operating pressure [bar] 6
Closing time [s] 0.14
Opening time [s] 0.14
Min. ambient temperature [°C] -40
Max. ambient temperature [°C] 80
Housing material PA 12
IP protection class 27
Diameter D [mm] 59.4
Tolerance Y ± 0,4
Height Z [mm] 70.5
Concentricity Ø V [mm] 0.5
Perpendicularity W [°] ± 1
Moment Mx max. [Nm] 2
Moment My max. [Nm] 2
Moment Mz max. [Nm] 0
Force Fx max. [N] 200
Force Fy max. [N] 200
Max. axial force Fz max. [N] 200
The gripping force can be set directly by the operating pressure. At a lower pressure than the nominal operating pressure, the full stroke cannot be achieved.
The size graduation varies by 1 mm respectively. Please note that the fastening thread A is independent of the size. (LOG 20-25: M14x1.5; LOG 26-63: M16x1; LOG 64-99: M20x1.5)
Information about other sizes can be found online.

Operating principle
Membrane

Housing material
PA 12

Base jaw material
PA 12

Actuation
pneumatic, with filtered compressed air as per ISO 8573-1:2010 [7:4:4].

Scope of delivery
Assembly instructions (operating manual with declaration of incorporation is available online)

Gripping force maintenance device
not possible