arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitteruserwarning wechat x-twitterxing youku youtube zoom
Změňte výběr země, abyste získali informace o produktech, službách a kontaktních osobách, které jsou důležité pro vaši lokalitu.
DPG-plus 80-2 Podobné zobrazení

DPG-plus 80-2

Utěsněné univerzální chapadlo

ID 1315981

Utěsněné univerzální chapadlo DPG-plus, Velikost: 80, pneumatický

  • Zdvih na čelist: 4 mm
  • Zavírací síla: 775 N
  • Otevírací síla: 860 N
  • Max. okolní teplota: 90 °C
Course par mors [mm] 4.0
Force à la fermeture [N] 775.0
Force à l'ouverture [N] 860.0
Force de fermeture (avec longueurs de doigt de 0 mm) [N] 900.0
Force d'ouverture (avec longueurs de doigt de 0 mm) [N] 1008.0
Poids [kg] 0.68
Volume du cylindre par course double [cm³] 22.5
Pression d'utilisation min. [bar] 2.5
Pression d'utilisation maximale [bar] 8.0
Pression d'utilisation nominale [bar] 6.0
Pression de purge d'air min. [bar] 0.2
Pression de purge d'air max. [bar] 0.5
Temps de fermeture [s] 0.05
Temps d'ouverture [s] 0.05
Longueur de doigt max. admissible [mm] 64.0
Poids de doigt max. admissible [kg] 0.5
Indice de protection IP 67
Température ambiante mini. [°C] 5.0
Température ambiant maxi. [°C] 90.0
Répétabilité [mm] 0.01
Classe salle blanche ISO-14644-1 5
Longueur X [mm] 98.5
Largeur Y [mm] 42.1
Hauteur Z [mm] 56.4
Moment Mx max. [Nm] 45.0
Moment My max. [Nm] 71.0
Moment Mz max. [Nm] 40.0
Force axiale max. Fz max. [N] 1125.0
Veuillez noter que pour obtenir une protection IP 67, la pince nécessite un tuyau supplémentaire pour évent ou une mise en supression à l'ouverture. Pour plus d'informations, reportez-vous à la notice de montage et d'utilisation. Alternativement, un filtre en métal fritté (fourni) monté sur le raccord de surpression peut éviter l'infiltration de particules > 0,12 mm. Cependant, cela réduit la classe de protection à IP 54.
Jusqu'à 100 cycles de préhension peuvent être nécessaires avant que toute la force de préhension indiquée soit disponible.

General notes about the series

Finger length
is measured from the reference surface as the distance P in direction to the main axis. The maximum permissible finger length applies until the nominal operating pressure is achieved. With higher pressures, the finger length must be reduced proportionally to the nominal operating pressure.

Note – tightness
Please note that to achieve an IP 67 protection class, the gripper requires an additional hose for ventilation or a switchable air purge connection. For detailed information, please refer to the assembly and operating manual. Alternatively, a sinter filter (supplied) mounted on the air purge connection can prevent the penetration of dirt particles > 0.12 mm. However, this reduces the protection class to IP 54.

Gripping force
is the arithmetic sum of the individual force applied to each jaw at distance P (see illustration).

Repeat accuracy
is defined as a distribution of the end Position for 100 consecutive strokes.

Workpiece weight
is calculated for force-fit gripping with a coefficient of static friction of 0.1 and a safety factor of 2 against workpiece slippage at acceleration due to gravity g. For form-fit or capture gripping, there are significantly higher permissible workpiece weights.

Closing and opening times
are movement times of the base jaws only, without application-specific gripper fingers. Valve switching times, hose fill times, or PLC reaction times are not included, and are to be considered when cycle times are calculated.

Operating principle
Wedge-hook kinematics

Housing material
Aluminum alloy, anodized

Base jaw material
Steel

Actuation
pneumatic, with filtered compressed air as per ISO 8573-1:2010 [7:4:4].

Warranty
36 months

Service life characteristics
on request

Scope of delivery
Centering sleeves, O-rings for direct connection, assembly instructions (operating manual with declaration of incorporation is available online)

Gripping force maintenance
possible by using the version with mechanical gripping force maintenance or pressure maintenance valve SDV-P