ID 1392572

FTN-AXIA80-DUAL SI-480-20/SI-1200-50

Force/torque sensor
Force/torque sensor FT-AXIA, Size: 80, EtherCAT, Ethernet, RS-422, RS-485

  • evaluation via: EtherNet
  • Range of measurement Fx, Fy: ± 480 N
  • Range of measurement Fz: ± 800 N
  • Range of measurement Mx, My: ± 20 Nm
  • Range of measurement Mz: ± 20 Nm
  • IP protection class: 64

Technical data FTN-AXIA80-DUAL SI-480-20/SI-1200-50

evaluation via EtherNet
Housing material stainless steel
Sensor cable 4 m, M8 plug on an M12 plug
Control line Y distributor 4 m, M12 plug on RJ-45 plug and 3-pin power supply (open wire strand)
Weight [kg] 0.68
Calibration 1 SI-480-20
Range of measurement Fx, Fy [N] ± 480
Range of measurement Fz [N] ± 800
Range of measurement Mx, My [Nm] ± 20
Range of measurement Mz [Nm] ± 20
Calibration 2 SI-1200-50
Range of measurement Fx, Fy [N] ± 1200
Range of measurement Fz [N] ± 2000
Range of measurement Mx, My [Nm] ± 50
Range of measurement Mz [Nm] ± 50
Overload Fx, Fy [N] ± 6000
Overload Fz [N] ± 10000
Overload Mx, My [Nm] ± 210
Overload Mz [Nm] ± 250
Resonant frequency Fx, Fy, Mz [Hz] 2500
Resonant frequency Fz, Mx, My [Hz] 2500
Resolution Fx, Fy [N] 0.4
Resolution Fz [N] 0.4
Resolution Mx, My [Nm] 0.01
Resolution Mz [Nm] 0.01
IP protection class 64
Diameter D [mm] 82
Height Z [mm] 25.4

General notes about the series

Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.

Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.

Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C

evaluation via
EtherCAT, Ethernet, RS-422, RS-485

Warranty
12 months

Product reviews FTN-AXIA80-DUAL SI-480-20/SI-1200-50

Please sign in to create reviews.

    Accessory FTN-AXIA80-DUAL SI-480-20/SI-1200-50

    The following components make the product FTN-AXIA80-DUAL SI-480-20/SI-1200-50 even more productive – the right addition for maximum functionality, flexibility, reliability and process safety.

    Downloads

    FTE-AXIA Commissioning instructions

    FTN-AXIA Commissioning instructions

    FT-AXIA 80 - URCap Software Manual

    FTR-AXIA 80 RS485 Operating Manual

    Product Overview Gripping Systems 2022

    FT-AXIA Transducer Manual

    New Products and Innovations 2022_Q1

    FTR-AXIA RS422 Commissioning instructions

    New Products and Innovations 2022_Q2

    FT / FT-AXIA Download Fyler QR-codes