arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitter userwarning wechat xing youku youtube zoom
Change the country selection to see information on the products, services and contact persons that are relevant for your location.
FTRS485-AXIA80-DUAL SI-75-4/SI-150-8 Illustration similar

FTRS485-AXIA80-DUAL SI-75-4/SI-150-8

Force/torque sensor

ID 1392581

Force/torque sensor FT-AXIA, Size: 80, EtherCAT, Ethernet, RS-422, RS-485

  • evaluation via: serial interface (RS-485)
  • Range of measurement Fx, Fy: ± 75 N
  • Range of measurement Fz: ± 235 N
  • Range of measurement Mx, My: ± 4 Nm
  • Range of measurement Mz: ± 4 Nm
  • IP protection class: 64
evaluation via serial interface (RS-485)
Housing material Aluminum
Weight [kg] 0.28
Calibration 1 SI-75-4
Range of measurement Fx, Fy [N] ± 75
Range of measurement Fz [N] ± 235
Range of measurement Mx, My [Nm] ± 4
Range of measurement Mz [Nm] ± 4
Calibration 2 SI-150-8
Range of measurement Fx, Fy [N] ± 150
Range of measurement Fz [N] ± 470
Range of measurement Mx, My [Nm] ± 8
Range of measurement Mz [Nm] ± 8
Overload Fx, Fy [N] ± 2350
Overload Fz [N] ± 7500
Overload Mx, My [Nm] ± 40
Overload Mz [Nm] ± 40
Resonant frequency Fx, Fy, Mz [Hz] 1500
Resonant frequency Fz, Mx, My [Hz] 1500
Resolution Fx, Fy [N] 0.04
Resolution Fz [N] 0.04
Resolution Mx, My [Nm] 0.002
Resolution Mz [Nm] 0.002
IP protection class 64
Diameter D [mm] 82
Height Z [mm] 25.4
yes

General notes about the series

Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.

Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.

Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C

evaluation via
EtherCAT, Ethernet, RS-422, RS-485

Warranty
12 months