arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram jobfinder linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitteruserwarning wechat x-twitterxing youku youtube zoom
Change the country selection to see information on the products, services and contact persons that are relevant for your location.
ERS 170-560-40-N-D-I Illustration similar

ERS 170-560-40-N-D-I

ID 310180

Universal rotary unit ERS, Size: 170, electrical, pneumatic and electric feed-through, Stroke measuring system interface: Sin/Cos 1Vss, Angle of rotation: > 360 °, Middle position: freely programmable

  • Torque: 4.7 Nm
  • Nominal current: 1.6 A
  • Power supply: 560 V
  • IP protection class: 40
Nominal torque [Nm] 4.7
Peak torque [Nm] 17.0
Nominal speed [1/min] 250.0
Max. rotational speed [1/min] 250.0
Max. permissible mass moment of inertia [kgm²] 0.2
Repeat accuracy [°] 0.01
Axial run-out [mm] 0.05
Run-out accuracy [mm] 0.05
Weight [kg] 6.3
Min. ambient temperature [°C] 5.0
Max. ambient temperature [°C] 55.0
IP protection class 40
Force Fx max. [N] 3750.0
Force Fz max. [N] 5000.0
Diameter D [mm] 170.0
Height Z [mm] 100.0
Moment My max. [Nm] 150.0
Intermediate circuit voltage [V] 560.0
Nominal current [A] 1.6
Max. current [A] 5.6
Encoder system Encoder (incremental)
Output signal Sin/Cos 1Vss
Number of pneumatic feed-throughs 1.0
Max. operating pressure [bar] 8.0
Number of electrical feed-throughs 8.0
Max. voltage (DC) [V] 24.0
Max. current [A] 2.0
All versions are also available with protection class IP54 upon request.
The peak torques serve as short-term drive reserves when accelerating and delaying.

General notes about the series

Swiveling times
The swiveling times are purely the times when the module moves from rest position to rest position. Delays caused by the PLC or the drive controller are not included and to be taken into consideration when determining cycle times. Load-dependent rest periods may have to be included in the cycle time.

Layout or control calculation
Verifying the sizing of the selected unit is necessary, since otherwise overloading can result. Please contact us for assistance.

Repeat accuracy
The repeat accuracy is defined as the spread of the target position after 100 consecutive positioning cycles.

Ambient conditions
The modules are primarily designed for the use in clean to slightly contaminated environments. Please note that the life time of the modules can shorten if they are used in harsh ambient conditions, and that SCHUNK cannot assume liability in such cases.

Safety notes
Caution: Magnetic field! This particularly applies for persons with implanted medical devices, such as pacemakers, hearing aids, etc.

Nominal currents
The rated currents can be permanently actuated. With regard to all the currents which are ranging above the nominal current up to the maximum current, the notes of the individual product documentation has to be respected.

Gehäusematerial
Aluminiumlegierung, oberflächenveredelt

Antrieb
Torquemotor, 3-phasig

Wegmesssystem
Berührungsloses, magnetisches Messsystem in inkrementeller Ausführung, Schnittstelle 1Vss

Antriebsregler
Beratung zu Parametereinstellungen für Antriebsregler BOSCH (IndraDrive, IndraDrive CS) und Siemens (Sinamics S120). Bereitstellung von Motordatenblätter für andere Antriebsregler. Inbetriebnahme-Unterstützung auf Anfrage.

Lieferumfang
Bei der Option Haltebremse werden zwei Mikroventile zur Ansteuerung der Bremse mitgeliefert, Sicherheitsinformationen (produktspezifische Anleitungen online verfügbar)

Gewährleistung
24 Monate