FTRS422-AXIA130 SI-2000-125 Illustration similar

FTRS422-AXIA130 SI-2000-125

Force/torque sensor

ID 1512783

Force/torque sensor FT-AXIA, Size: 130, EtherCAT, Ethernet, RS-422, RS-485

  • evaluation via: serial interface (RS-422)
  • Measuring range Fx, Fy: ± 2000 N
  • Measuring range Fz: ± 4000 N
  • Measuring range Mx, My: ± 125 Nm
  • Measuring range Mz: ± 125 Nm
  • IP protection class: 67
Sensor cable 5 m, M12 connector on an M12 connector
Weight [kg] 0.86
Calibration 1 SI-2000-125
Control line Y distributor 4 m, M12 plug on RJ-45 plug and 3-pin power supply (open wire strand)
Height Z [mm] 39.2
Diameter D [mm] 130.0
Resolution Fx, Fy [N] 0.625
Resolution Fz [N] 0.625
Resolution Mx, My [Nm] 0.025
evaluation via serial interface (RS-422)
Measuring range Fx, Fy [N] ± 2000
Measuring range Fz [N] ± 4000
Resolution Mz [Nm] 0.025
Measuring range Mx, My [Nm] ± 125
Measuring range Mz [Nm] ± 125
Overload Fx, Fy [N] ± 10000
Overload Fz [N] ± 20000
Overload Mz [Nm] ± 620
Resonant Frequency Fx, Fy, Mz [Hz] 2500.0
Resonant Frequency Fz, Mx, My [Hz] 4000.0
Overload Mx, My [Nm] ± 620
IP protection class 67
Housing material Aluminum

General notes about the series

Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.

Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.

Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C

evaluation via
EtherCAT, Ethernet, RS-422, RS-485

Warranty
12 months