OPS-100
ID 321130
- Deflection rotatory: ± 360 °
- Force Fd max.: 1500 N
Technical details
| Axial deflection [mm] | 14.0 |
|---|---|
| Angular deflection [°] | ± 12 |
| Deflection rotatory [°] | ± 360 |
| Min. triggering moment, angular Mx, My [Nm] | 5.0 |
| Max. force Fd [N] | 1500.0 |
| Min. supply voltage [V] | 10.0 |
| Max. supply voltage [V] | 30.0 |
| Repeat accuracy [mm] | ± 0.02 |
| Responsiveness [mm] | 0.1 |
| Repeat accuracy, rotary [min] | 5.0 |
| Min. operating pressure [bar] | 0.5 |
| Max. operating pressure [bar] | 5.0 |
| Weight [kg] | 0.7 |
| Min. ambient temperature [°C] | 5.0 |
| Max. ambient temperature [°C] | 60.0 |
| Diameter D [mm] | 100.0 |
| Height Z [mm] | 63.0 |
| Moment Mx max. [Nm] | 19.0 |
| Moment My max. [Nm] | 19.0 |
| Moment Mz max. [Nm] | 50.0 |
Dimensions and maximum loads
Trigger moment Mx, My, Mz
Triggering force Fd
Dimensions and maximum loads
The design of a collision sensor is defined by the occuring forces and moments in your application.
Trigger moment Mx, My, Mz
- X-axis:
- Pressure
- Y-axis:
- Moments
Triggering force Fd
- X-axis:
- Pressure
- Y-axis:
- Force
Informations générales concernant la gamme
Conditions ambiantes extrêmes
Veuillez noter que l'utilisation dans des conditions ambiantes difficiles (ex. dans une zone avec liquide de coupe, poussière de rectification et de fonte...) peut considérablement réduire la durée de vie des produits, et n'est pas couvert par la garantie. Cependant, dans de nombreux cas nous avons une solution. N'hésitez pas à nous contacter.
Actionnement
pneumatique, par air comprimé filtré selon la norme ISO 8573-1:2010 [7:4:4].
Etendue de la livraison
Capteur de collision et de surcharge dans la variante commandée, éléments de connexion électrique et informations de sécurité. Les instructions spécifiques aux produits peuvent être téléchargées sur schunk.com/downloads-manuals.
Garantie
24 mois