arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram jobfinder linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitteruserwarning wechat x-twitterxing youku youtube zoom
Change the country selection to see information on the products, services and contact persons that are relevant for your location.
APS-Z80-M8 Illustration similar

APS-Z80-M8

Analog position sensor

ID 302070

In stock
Analog position sensor APS-Z80

  • Cable length: 0.3 m
  • Sensor cables KA: M8 connector, 3-pin
  • Nominal voltage: 24 V
Measuring principle inductive
Number of switching points Analog
Voltage output yes
Min. output voltage [V] 0.5
Max. output voltage [V] 9.5
Linearity [%] ± 5
Repeat accuracy R of final value maximum ±3%
Limit frequency [Hz] 1000.0
Min. ambient temperature [°C] -10.0
Max. ambient temperature [°C] 70.0
LED display in sensor no
Max. measuring speed [m/s] 20.0
Response time/type. Switching time [ms] 0.5
Nominal voltage [V] 24.0
Min. operating voltage [V] 15.0
Max. voltage [V] 30.0
Max. ripple (% of Ue) ±15%
Type of voltage DC
Nominal current [mA] 8.0
Min. load resistance RL [kΩ] 2.0
Short circuit protection yes
Protected against polarity reversal yes
Housing material Steel, rustproof
Material of the active surface PBT
Cable connector/cable end M8 connector, 3-pin
Cable length [m] 0.3
Cable diameter [mm] 3.1
Cable sheath material PUR
IP protection class 67
Protection class 2
CE yes
The typical voltage value at the output ranges between 0.5 and 9.5 volts. Depending on the gripper and gripper size, the voltage may be higher or lower.