arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitteruserwarning wechat x-twitterxing youku youtube zoom
Changez la sélection du pays pour voir les informations sur les produits, les services et les interlocuteurs pertinents pour votre localisation.
FTE-AXIA90 SI-1000-50 Illustration similaire

FTE-AXIA90 SI-1000-50

Capteur de force/couple

ID 1512827

Renseignez-vous dès maintenant
Ce produit ne peut pas être commandé en ligne
Capteur de force/couple FT-AXIA, Taille: 90, EtherCAT, Ethernet, RS-422, RS-485

  • Contrôle via: EtherCAT
  • Plage de mesure Fx, Fy: ± 1000 N
  • Plage de mesure Fz: ± 2000 N
  • Plage de mesure Mx, My: ± 50 Nm
  • Plage de mesure Mz: ± 50 Nm
  • Indice de protection IP: 67
Sensor cable 4 m, M8 plug on an M12 plug
Weight [kg] 0.744
Calibration 1 SI-1000-50
Control line Y distributor 4 m, M12 plug on RJ-45 plug and 3-pin power supply (open wire strand)
Height Z [mm] 26.9
Diameter D [mm] 89.9
Resolution Fx, Fy [N] 0.4
Resolution Fz [N] 0.4
Resolution Mx, My [Nm] 0.01
evaluation via EtherCAT
Measuring range Fx, Fy [N] ± 1000
Measuring range Fz [N] ± 2000
Resolution Mz [Nm] 0.01
Measuring range Mx, My [Nm] ± 50
Measuring range Mz [Nm] ± 50
Overload Fx, Fy [N] ± 5000
Overload Fz [N] ± 10000
Overload Mz [Nm] ± 250
Resonant Frequency Fx, Fy, Mz [Hz] 2300.0
Resonant Frequency Fz, Mx, My [Hz] 2900.0
Overload Mx, My [Nm] ± 250
IP protection class 67
Housing material Aluminum

General notes about the series

Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.

Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.

Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C

evaluation via
EtherCAT, Ethernet, RS-422, RS-485

Warranty
12 months