DDF-I-040-S-V1-P1
ID 325060
- Nombre de passages de fluide: 1
- Nombre de passages électriques: 4
- Poids de pièce recommandé: 20 kg
- Force Fz max.: 800 N
- Force Fd max.: 4000 N
Détails techniques
| Charge recommandée [kg] | 20.0 |
|---|---|
| Vitesse d'entraînement max. [1/min] | 120.0 |
| Vitesse de rotation max. [°/s] | 720.0 |
| Couple permanent [Nm] | 2.5 |
| Couple de desserrage [Nm] | 3.5 |
| Mouvement de rotation [°] | > 360 |
| Poids [kg] | 1.9 |
| Raccordement côté robot | ISO 9409-1-40-4-M6 |
| Température ambiante mini. [°C] | 5.0 |
| Température ambiant maxi. [°C] | 60.0 |
| Nombre de passages pneumatiques | 1.0 |
| Nombre de passages pneumatiques | 1.0 |
| Pression max. par raccord [bar] | 10.0 |
| Débit à 6 bars (par canal) [l/min] | 500.0 |
| Tension [V DC] | 48.0 |
| Intensité [A] | 0.5 |
| Tension [V DC] | 48.0 |
| Intensité [A] | 4.0 |
| Moment Mx max. [Nm] | 60.0 |
| Moment My max. [Nm] | 60.0 |
| Moment Mz max. [Nm] | 40.0 |
| Force Fz max. [N] | 800.0 |
| Force Fd max. [N] | 4000.0 |
| Force latérale max. Fq max. [N] | 200.0 |
Suivant la cas, cela peut ne pas répondre complémentent aux normes de câble de signaux d'installations en BUS. De plus, ni le temps de transmission du signal ni l'amortissement du signal ne peuvent être définis avec exactitude (voir la notice d'utilisation pour les détails).
Pour une transmission optimale des signaux PROFIBUS, les mesures suivantes sont conseillées :
Max. loads
Max. loads
This is the max. total of all loads (acceleration forces and torques, process forces, emergency stops, etc.), which can affect a rotary feed-through, in order to ensure error-free function.
General notes about the series
Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.
Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.
Mounting
Standardized ISO 9409 interface (robot-side)
Media transmission
Pneumatic, Vacuum and Bus signals
Housing
high-strength, hard-coated aluminum alloy
Scope of delivery
Operating and maintenance instruction, manufacturer’s declaration
Warranty
24 months