SKE 22
ID 351102
- Couple: 0.75 Nm
Détails techniques
| Angle de rotation [°] | 90 |
|---|---|
| Réglage des fins de course [°] | 5 |
| Couple [Nm] | 0.75 |
| Indice de protection IP | 30 |
| Poids [kg] | 0.2 |
| Temps de rotation (1x angle de rotation nominal) sans charge embarquée [s] | 0.8 |
| Consommation de fluide (2x angle nominal) [cm³] | 20.0 |
| Pression d'utilisation nominale [bar] | 4.0 |
| Pression d'utilisation min. [bar] | 1.0 |
| Pression d'utilisation maximale [bar] | 6.0 |
| Diamètre de flexible à utiliser | 4.3 x 3 x 0.65 |
| Température ambiante mini. [°C] | 5.0 |
| Température ambiant maxi. [°C] | 50.0 |
| Répétabilité [°] | 0.03 |
| Longueur X [mm] | 74.0 |
| Largeur Y [mm] | 56.0 |
| Hauteur Z [mm] | 56.0 |
| Moment My max. [Nm] | 19.0 |
| Force Fx max. [N] | 380.0 |
Dimensions et charges max.
Couple
Dimensions et charges max.
Les moments et les forces indiqués correspondent à des valeurs statiques et peuvent survenir simultanément. Le réglage de la vitesse par les limiteurs de débit doit être effectué pour s'assurer que le mouvement de rotation est réalisé sans impact ni rebond. Dans le cas contraire, la durée de vie peut être réduite.
Couple
- Axe X:
- Pression
- Axe Y:
- Couple
General notes about the series
Repeat accuracy
is defined as a distribution of the end position for 100 consecutive cycles.
Swiveling time
is the rotation time of pinion/flange around the nominal rotation angle. Valve switching times, hose filling times, or PLC reaction times are not included and are to be considered when cycle times are calculated.
Torque
is specified in relation to the rotary axis and at a nominal operating pressure of 4 bar.
Direct adaption of grippers
Some RH grippers can be directly flange-mounted to the SKE without an adapter plate. In this case, please note the screw connection diagram.
Housing material
Aluminum
Material of the (internal) functional components
Steel
Actuation
pneumatic, with filtered compressed air as per ISO 8573-1:2010 [7:4:4].
Operating principle
double acting piston with geared transmission
Scope of delivery
Small parts for mounting, flow control couplings, Assembly and Operating Manual with Manufacturer's Declaration.
Warranty
24 months