FTN-AXIA80-DUAL SI-480-20/SI-1200-50
ID 1392572
Productos alternativos:
- Análisis vía: EtherNet
- Margen de medición Fx, Fy: ± 480 N
- Margen de medición Fz: ± 800 N
- Margen de medición Mx, My: ± 20 Nm
- Margen de medición Mz: ± 20 Nm
- Clase de protección IP: 64
Información técnica
| Análisis vía | EtherNet |
|---|---|
| Material de la carcasa | Acero inoxidable |
| Cable del sensor | 4 m, conector M8 en un conector M12 |
| Línea de control | Distribuidor Y 4 m, conector M12 en conector RJ-45 y suministro de energía de 3 contactos (cable abierto) |
| Peso [kg] | 0.68 |
| Calibración 1 | SI-480-20 |
| Margen de medición Fx, Fy [N] | ± 480 |
| Margen de medición Fz [N] | ± 800 |
| Margen de medición Mx, My [Nm] | ± 20 |
| Margen de medición Mz [Nm] | ± 20 |
| Calibración 2 | SI-1200-50 |
| Margen de medición Fx, Fy [N] | ± 1200 |
| Margen de medición Fz [N] | ± 2000 |
| Margen de medición Mx, My [Nm] | ± 50 |
| Margen de medición Mz [Nm] | ± 50 |
| Sobrecarga Fx, Fy [N] | ± 6000 |
| Sobrecarga Fz [N] | ± 10000 |
| Sobrecarga Mx, My [Nm] | ± 210 |
| Sobrecarga Mz [Nm] | ± 250 |
| Frecuencia de resonancia Fx, Fy, Mz [Hz] | 2500.0 |
| Frecuencia de resonancia Fz, Mx, My [Hz] | 2500.0 |
| Resolución Fx, Fy [N] | 0.4 |
| Resolución Fz [N] | 0.4 |
| Resolución Mx, My [Nm] | 0.01 |
| Resolución Mz [Nm] | 0.01 |
| Clase de protección IP | 64 |
| Diámetro D [mm] | 82.0 |
| Altura Z [mm] | 25.4 |
Dimensions and maximum loads
Dimensions and maximum loads
All forces and torques acting on the sensor must be within the specified measurement range.
Exceeding the measurement range will reduce the maximum number of load cycles and may lead to damage of the sensor. Please contact us if your application exceeds the measurement range.
General notes about the series
Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.
Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.
Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C
evaluation via
EtherCAT, Ethernet, RS-422, RS-485
Warranty
12 months