FTN-AXIA90 SI-1000-50
ID 1512819
Productos alternativos:
- Análisis vía: EtherNet
- Margen de medición Fx, Fy: ± 1000 N
- Margen de medición Fz: ± 2000 N
- Margen de medición Mx, My: ± 50 Nm
- Margen de medición Mz: ± 50 Nm
- Clase de protección IP: 67
Información técnica
| Auswertung via | EtherNet |
|---|---|
| Gehäusematerial | Alluminio |
| Sensorleitung | 4 m, tappo M8 su un tappo M12 |
| Steuerungsleitung | Distributore Y 4 m, tappo M12 su tappo RJ-45 e alimentazione di corrente a 3 pin (treccia scoperta) |
| Eigenmasse [kg] | 0.744 |
| Kalibrierung 1 | SI-1000-50 |
| Messbereich Fx, Fy [N] | ± 1000 |
| Messbereich Fz [N] | ± 2000 |
| Messbereich Mx, My [Nm] | ± 50 |
| Messbereich Mz [Nm] | ± 50 |
| Überlast Fx, Fy [N] | ± 5000 |
| Überlast Fz [N] | ± 10000 |
| Überlast Mx, My [Nm] | ± 250 |
| Überlast Mz [Nm] | ± 250 |
| Resonanzfrequenz Fx, Fy, Mz [Hz] | 2300.0 |
| Resonanzfrequenz Fz, Mx, My [Hz] | 2900.0 |
| Auflösung Fx, Fy [N] | 0.4 |
| Auflösung Fz [N] | 0.4 |
| Auflösung Mx, My [Nm] | 0.01 |
| Auflösung Mz [Nm] | 0.01 |
| Schutzart IP | 67 |
| Durchmesser D [mm] | 89.9 |
| Höhe Z [mm] | 26.9 |
Dimensions and maximum loads
Dimensions and maximum loads
All forces and torques acting on the sensor must be within the specified measurement range.
Exceeding the measurement range will reduce the maximum number of load cycles and may lead to damage of the sensor. Please contact us if your application exceeds the measurement range.
General notes about the series
Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.
Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.
Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C
evaluation via
EtherCAT, Ethernet, RS-422, RS-485
Warranty