arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram jobfinder linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitteruserwarning wechat x-twitterxing youku youtube zoom
Cambie la selección del país para ver la información sobre los productos, servicios y personas de contacto relevantes para su ubicación.
FTN-AXIA90 SI-1000-50 Similar a la imagen

FTN-AXIA90 SI-1000-50

Sensor de fuerza/momentos

ID 1512819

Sensor de fuerza/momentos FT-AXIA, Tamaño: 90, EtherCAT, Ethernet, RS-422, RS-485

  • Análisis vía: EtherNet
  • Margen de medición Fx, Fy: ± 1000 N
  • Margen de medición Fz: ± 2000 N
  • Margen de medición Mx, My: ± 50 Nm
  • Margen de medición Mz: ± 50 Nm
  • Clase de protección IP: 67
Auswertung via EtherNet
Gehäusematerial Alluminio
Sensorleitung 4 m, tappo M8  su un tappo M12
Steuerungsleitung Distributore Y 4 m, tappo M12 su tappo RJ-45 e alimentazione di corrente a 3 pin (treccia scoperta)
Eigenmasse [kg] 0.744
Kalibrierung 1 SI-1000-50
Messbereich Fx, Fy [N] ± 1000
Messbereich Fz [N] ± 2000
Messbereich Mx, My [Nm] ± 50
Messbereich Mz [Nm] ± 50
Überlast Fx, Fy [N] ± 5000
Überlast Fz [N] ± 10000
Überlast Mx, My [Nm] ± 250
Überlast Mz [Nm] ± 250
Resonanzfrequenz Fx, Fy, Mz [Hz] 2300.0
Resonanzfrequenz Fz, Mx, My [Hz] 2900.0
Auflösung Fx, Fy [N] 0.4
Auflösung Fz [N] 0.4
Auflösung Mx, My [Nm] 0.01
Auflösung Mz [Nm] 0.01
Schutzart IP 67
Durchmesser D [mm] 89.9
Höhe Z [mm] 26.9

General notes about the series

Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.

Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.

Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C

evaluation via
EtherCAT, Ethernet, RS-422, RS-485

Warranty
12 months