PR 2-090-51-PB-I Illustration similar

PR 2-090-51-PB-I

ID 359510

범용 회전 유닛 PR 2, 크기: 90, 전동식, 정지 유지 브레이크 포함, 통신 인터페이스 : PROFIBUS, 회전 각도: > 360 °, 중간 위치: 자유로운 프로그래밍 가능

  • 기어 비율: 51:1
  • 토크: 12.8 Nm
  • 정격 전류: 13 A
  • 전원공급장치: 24 V
정격 토크 [Nm] 12.8
최대 토크 [Nm] 24.0
안정적 토크 [Nm] 16.8
정격 속도 [1/min] 78.0
최대 회전 속도 [1/min] 78.0
관성의 최대 허용 가능한 질량 모멘트 [kgm²] 0.47
반복 정밀도 [°] 0.03
전송 51:1
모멘트 My 최대 [Nm] 80.0
포스 Fx 최대 [N] 800.0
포스 Fz 최대 [N] 590.0
브레이크
중량 [kg] 3.7
최소 주위 온도 [°C] 5.0
최대 주위 온도 [°C] 50.0
IP 보호등급 40
길이 X [mm] 126.0
너비 Y [mm] 90.0
높이 Z [mm] 180.5
정격 전압 [V] 24.0
정격 전류 [A] 13.0
최대 전류 [A] 23.0
전자 장치 제어 통합형
전원공급장치 [V] 24.0
인코더 시스템 인코더(증분형)
PROFIBUS 인터페이스 [Mbit/s] 12.0
USB 인터페이스 호스트/장치
디지털 입력 수 2.0
"최대 전류" 값은 과부하 작동 시 최고 전류를 나타내며 정격 전류는 실효 전류입니다.
주변 온도, 속도, 가속 및 관성에 따라서 적절한 유휴 시간이 제공되어야 합니다.

General notes about the series

Swiveling times
are purely the times of the module to rotate from rest position to rest position. Relay switching times or PLC reaction times are not included in the above times and must be taken into consideration when determining cycle times. Load-dependent rest periods may have to be included in the cycle time.

Repeat accuracy
Is defined as the spread of the target position after 100 consecutive positioning cycles.

Nominal currents
can be permanently actuated. With regard to all the currents which are ranging above the nominal current up to the maximum current, the notes of the individual product documentation has to be respected.

Electrical brake
The installed, electric holding brake serves to fix and hold the position in case of power failure up to the rated torque. It cannot cover any complete safety functions.

Peak torque
The peak torques serve as short-term drive reserves when accelerating and delaying.

Housing material
Aluminum alloy, coated

Actuation
servo-electric, via brushless DC servomotor

Operating principle
Harmonic drive® gear driven directly via brushless DC servomotor

Scope of delivery
DVD with SCHUNK software and commissioning assistant, includes assembly and operating manual, declaration of incorporation, functional module for control via Siemens S7.

Warranty
24 months