FTN-AXIA90 SI-1000-50
Ident.-Nr. 1512819
Alternative Produkte:
- Auswertung via: EtherNet
- Messbereich Fx, Fy: ± 1000 N
- Messbereich Fz: ± 2000 N
- Messbereich Mx, My: ± 50 Nm
- Messbereich Mz: ± 50 Nm
- Schutzart IP: 67
Technische Details
| Auswertung via | EtherNet |
|---|---|
| Gehäusematerial | Aluminium |
| Sensorleitung | 4 m, M8-Stecker auf M12-Stecker |
| Steuerungsleitung | Y-Verteiler 4 m, M12-Stecker auf RJ-45-Stecker und 3-polige Spannungsversorgung (offene Litze) |
| Eigenmasse [kg] | 0.744 |
| Kalibrierung 1 | SI-1000-50 |
| Messbereich Fx, Fy [N] | ± 1000 |
| Messbereich Fz [N] | ± 2000 |
| Messbereich Mx, My [Nm] | ± 50 |
| Messbereich Mz [Nm] | ± 50 |
| Überlast Fx, Fy [N] | ± 5000 |
| Überlast Fz [N] | ± 10000 |
| Überlast Mx, My [Nm] | ± 250 |
| Überlast Mz [Nm] | ± 250 |
| Resonanzfrequenz Fx, Fy, Mz [Hz] | 2300.0 |
| Resonanzfrequenz Fz, Mx, My [Hz] | 2900.0 |
| Auflösung Fx, Fy [N] | 0.4 |
| Auflösung Fz [N] | 0.4 |
| Auflösung Mx, My [Nm] | 0.01 |
| Auflösung Mz [Nm] | 0.01 |
| Schutzart IP | 67 |
| Durchmesser D [mm] | 89.9 |
| Höhe Z [mm] | 26.9 |
Dimensions and maximum loads
Dimensions and maximum loads
All forces and torques acting on the sensor must be within the specified measurement range.
Exceeding the measurement range will reduce the maximum number of load cycles and may lead to damage of the sensor. Please contact us if your application exceeds the measurement range.
General notes about the series
Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.
Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.
Measuring accuracy
< 2% of the upper limit value of the measuring range at 22 °C
evaluation via
EtherCAT, Ethernet, RS-422, RS-485
Warranty
12 months