ERD 12-40-D-H-N Illustration similaire

ERD 12-40-D-H-N

ID 331250

Unité de rotation miniature ERD, Taille: 12, électrique, passages pneumatiques et électriques, Angle de rotation: > 360 °, Position intermédiaire: librement programmable

  • Couple: 1.2 Nm
  • Courant nominal: 1.09 A
  • Alimentation électrique: 530 V
  • Indice de protection IP: 40
Angle de rotation [°] > 360
Couple nominal [Nm] 1.2
Couple de pointe [Nm] 3.6
Vitesse de rotation max. [1/min] 600.0
moment d'inertie de masse maximum admissible [kgm²] 0.011
Répétabilité [°] 0.01
Poids [kg] 1.8
Température ambiante mini. [°C] 10.0
Température ambiant maxi. [°C] 40.0
Indice de protection IP 40
Catégorie salle blanche ISO 14644-1:2015 2
Force Fx max. [N] 150.0
Force Fz max. [N] 150.0
Longueur X [mm] 68.0
Largeur Y [mm] 60.0
Hauteur Z [mm] 164.0
Moment My max. [Nm] 2.5
Tension circuit intermédiaire [V] 530.0
Courant nominal [A] 1.6
Courant max. [A] 5.1
Système de mesure Encodeur (absolu)
Signal de sortie HIPERFACE®
Certification SIL non certifiées
Nombre de passages pneumatiques 2.0
Pression d'utilisation maximale [bar] 6.0
Nombre de passages électriques 4.0
Tension max. (DC) [V] 60.0
Courant max. [A] 1.0
Les couples de pointe servent de réserve d'entraînement à court terme lors de l'accélération et du ralentissement.

General notes about the series

Swiveling times
The swiveling times are purely the times when the module moves from rest position to rest position. Delays caused by the PLC or the drive controller are not included and to be taken into consideration when determining cycle times. Load-dependent rest periods may have to be included in the cycle time.

Layout or control calculation
Verifying the sizing of the selected unit is necessary, since otherwise overloading can result. Please contact us for assistance.

Repeat accuracy
The repeat accuracy is defined as the spread of the target position after 100 consecutive positioning cycles.

Ambient conditions
The modules are primarily designed for the use in clean to slightly contaminated environments. Please note that the life time of the modules can shorten if they are used in harsh ambient conditions, and that SCHUNK cannot assume liability in such cases.

Safety notes
Caution: Magnetic field! This particularly applies for persons with implanted medical devices, such as pacemakers, hearing aids, etc.

Nominal currents
The rated currents can be permanently actuated. With regard to all the currents which are ranging above the nominal current up to the maximum current, the notes of the individual product documentation has to be respected.

Cleanroom class ISO 14644-1:2015

Housing material
Aluminum alloy, coated

Drive
Torque motor, 3-phase

Stroke measuring system
Absolute path measuring system, multiturn version, with HIPERFACE®, EnDat2.2, and DRIVE-CLiQ interfaces (via EnDat 2.2 + signal converter)

Drive controller
Consultation on parameter settings for drive controllers from BOSCH (EcoDrive CS, IndraDrive and IndraDrive CS) and Siemens (Sinamics S120). Provision of motor data sheets for other drive controllers. Commissioning support on request.

Scope of delivery
Enclosed accessory pack containing centering sleeve, assembly and operating manual, commissioning DVD for SCHUNK motors

Warranty