ELM 23-H070-HP-ASP
ID 314381
- Course max.: 70 mm
- Force max. d'entraînement: 137 N
- Courant nominal: 3.8 A
Détails techniques
| Concept d'entraînement | Entraînement direct linéaire |
|---|---|
| Course max. [mm] | 70.0 |
| Force max. d'entraînement [N] | 137.0 |
| Force nominale [N] | 48.0 |
| Couple maximal max. (horizontalement) [kg] | 3.0 |
| Répétabilité [mm] | ± 0.05 |
| Vitesse de rotation max. [m/s] | 1.5 |
| Accélération max. [m/s²] | 40.0 |
| Courant max. [A] | 11.0 |
| Courant nominal [A] | 3.8 |
| Température ambiante mini. [°C] | 10.0 |
| Température ambiant maxi. [°C] | 40.0 |
| Poids [kg] | 1.61 |
| Longueur totale [mm] | 70.5 |
| Distance N (pour la charge de moment) [mm] | 70.5 |
| Longueur X [mm] | 298.0 |
| Largeur Y [mm] | 62.0 |
| Hauteur Z [mm] | 54.0 |
| Moment Mx max. [Nm] | 20.0 |
| Moment My max. [Nm] | 100.0 |
| Moment Mz max. [Nm] | 100.0 |
| Force Fy max. [N] | 2000.0 |
| Force Fz max. [N] | 2000.0 |
| Force axiale max. Fz max. [N] | 2000.0 |
| Force -Fz max. [N] | 2000.0 |
| Version avec frein de maintien | Oui |
Dimensions et charges max.
Temps de déplacement
Dimensions et charges max.
Les forces et les couples indiqués sont des valeurs maximales pour une charge individuelle. Si plusieurs forces et/ou couples sont appliqués simultanément, les valeurs individuelles maximales autorisées sont inférieures.
Temps de déplacement
- Axe X:
- Course
- Axe Y:
- Temps de déplacement
General notes about the series
Safety notes
Caution: Magnetic field! This particularly applies for persons with implanted medical devices, such as pacemakers, hearing aids, etc.
Repeat accuracy
defined as the spread of the target position after 100 consecutive positioning cycles under constant conditions.
Ambient conditions
The modules are mainly designed for the use in clean ambient conditions. Please note that the life time of the modules can shorten if they are used in harsh ambient conditions, and that SCHUNK cannot assume liability in such cases. Please contact us for assistance.
Layout or control calculation
of the selected unit is absolutely necessary, since otherwise overloading can result. Please contact us for assistance.
Housing material
Aluminum alloy, coated
Guidance
Profiled rail guide
Drive
Linear direct drive
Scope of delivery
Accessory pack with centering sleeves and assembly and operating manual with declaration of incorporation
Drive controller
LinMot® drive controllers are used by default.
Warranty
24 months