OPR-101-P00-S
ID 321405
该产品是旧版本。
Anti-collision and overload protection sensor OPR, Size: 101, resetting: automatisch, Splash-proof version
- Deflection rotatory: ± 25 °
- Force Fd max.: 2700 N
- IP protection class: 65
技术细节
| Axial deflection [mm] | 10.0 |
|---|---|
| Angular deflection [°] | ± 12 |
| Deflection rotatory [°] | ± 25 |
| Min. triggering moment, angular Mx, My [Nm] | 27.0 |
| Min. triggering torque, rotatory Mz [Nm] | 31.0 |
| Min. triggering force, axial Fd [N] | 605.0 |
| Max. force Fd [N] | 2700.0 |
| Min. supply voltage [V] | 10.0 |
| Max. supply voltage [V] | 30.0 |
| Repeat accuracy [mm] | ± 0.025 |
| Responsiveness [mm] | 0.5 |
| Repeat accuracy, rotary [min] | 5.0 |
| Min. operating pressure [bar] | 1.4 |
| Max. operating pressure [bar] | 6.2 |
| Weight [kg] | 1.2 |
| Min. ambient temperature [°C] | 5.0 |
| Max. ambient temperature [°C] | 60.0 |
| Diameter D [mm] | 100.1 |
| Height Z [mm] | 63.0 |
| Moment Mx max. [Nm] | 120.0 |
| Moment My max. [Nm] | 120.0 |
| Moment Mz max. [Nm] | 130.0 |
| Splash-proof version | yes |
Dimensions and maximum loads
Trigger moment Mx, My, Mz
Triggering force Fd
Moment loading
Dimensions and maximum loads
The design of a collision sensor is defined by the occuring forces and moments in your application.
Trigger moment Mx, My, Mz
- X 轴:
- Pressure
- Y 轴:
- Moments
Triggering force Fd
- X 轴:
- Pressure
- Y 轴:
- Force
Moment loading
The diagram shows the angular deflection of the OPR according to the moment Mx, My with maximum permissible operating pressure.
- X 轴:
- Angle in degrees
- Y 轴:
- Mx,y in Nm
モデルシリーズに関する一般注意事項
厳しい環境条件
厳しい環境条件 (クーラント関連、鋳造屑および研削屑など) 下で使用すると、ユニットの製品寿命が大幅に短くなる可能性があり、この場合は保証の対象外となることにご注意ください。しかしながら、多くの場合シュンクがソリューションを見つけることも可能です。サポートについてはお気軽にお問い合わせください。
作動
空圧式、フィルターを通した圧縮空気、ISO 8573-1:2010 [7:4:4] に準拠。
作動方式
内蔵シリンダーピストン
納品内容
注文品のバリアントには衝突・過負荷センサー、電気接続用エレメント、安全情報が含まれています。製品固有の説明書は、schunk.com/downloads-manualsからダウンロードいただけます。
保証
24 カ月