EMH-RP 045-B
ID 1351490
- 能源供应: 24 V
- 磁力区域: 10.75 cm²
- 磁路: 3.8 A
- 最高环境温度: 50 °C
技术细节
| 保持力 [N] | 1360.0 |
|---|---|
| 磁力区域 [cm²] | 10.75 |
| 水平磁力面的有效负载 [kg] | 22.5 |
| 垂直磁力面的有效负载 [kg] | 9.0 |
| 每分钟启动 5 次时模块温度升高 [°C] | 11.0 |
| 每分钟启动 15 次时模块温度升高 [°C] | 28.0 |
| 启动时间 [ms] | 300.0 |
| 最低环境温度 [°C] | 5.0 |
| 最高环境温度 [°C] | 50.0 |
| 重量 [kg] | 1.5 |
| IP 防护等级 | 52 |
| 额定电压 [V] | 24.0 |
| 电压类型 | DC |
| 最大工作电流 [A] | 3.8 |
| 额定电流逻辑 [A] | 0.15 |
| 控制器电子元件 | 配套 |
| 长度 X [mm] | 64.0 |
| 宽度 Y [mm] | 64.0 |
| 高度 Z [mm] | 128.0 |
Dimensions and maximum loads
工件厚度
Air gap
Increase in temperature
Dimensions and maximum loads
工件厚度
- X 轴:
- 工件厚度
- Y 轴:
- Holding force
Air gap
- X 轴:
- Air gap
- Y 轴:
- Holding force
Increase in temperature
- X 轴:
- Activations
- Y 轴:
- Increase in temperature
General notes about the series
Layout or control calculation
Verifying the sizing of the selected unit is necessary, since otherwise overloading can result. Please contact us for assistance.
Activation time
The activation time is the time required to reverse the polarity of the permanent magnets.
Ambient conditions
The modules are primarily designed for the use in clean to slightly contaminated environments. Please note that the life time of the modules can shorten if they are used in harsh ambient conditions, and that SCHUNK cannot assume liability in such cases.
Operating principle
Magnetization of permanent magnets
Housing material
Aluminum/steel
Base jaw material
Steel
Actuation
Electrical current pulse for activation and deactivation of the system
Warranty
24 months
Service life characteristics
on request
Scope of delivery
Assembly and Operating Manual with Declaration of Incorporation, centering sleeves