arrow calendar cartcheck checkmark close configure contact danger download external_link facebook globeinfo instagram jobfinder linkedin logo_claim logout mail menuminus navigation pin play plus rss searchshaft success twitteruserwarning wechat x-twitterxing youku youtube zoom
Altere a seleção de país para ver informações sobre produtos, serviços e pessoas de contato relevantes para sua localização.
LGR 25 Ilustração semelhante

LGR 25

Garra radial

N.º de identificação 312974

Garra radial LGR, Tamanho: 25, pneumático

  • Ângulo de abertura: 90 °
  • Momento de fechamento: 4 Nm
  • Máx. temperatura ambiente: 90 °C
Closing force (with finger lengths of 0 mm) [N] 285.0
Opening angle per jaw [°] 90.0
Closed angle per jaw up to [°] 4.0
Closing moment [Nm] 4.0
Weight [kg] 0.4
Recommended workpiece weight [kg] 0.52
Cylinder volume per double stroke [cm³] 13.0
Min. operating pressure [bar] 2.0
Max. operating pressure [bar] 8.0
Nominal operating pressure [bar] 6.0
Closing time [s] 0.1
Opening time [s] 0.12
Max. permissible finger length [mm] 50.0
Max. permissible weight per finger [kg] 0.1
IP protection class 20
Min. ambient temperature [°C] 5.0
Max. ambient temperature [°C] 90.0
Repeat accuracy [mm] 0.02
Moment Mx max. [Nm] 3.7
Moment Mz max. [Nm] 2.5
Max. axial force Fz max. [N] 58.0

General notes about the series

Closing moment
is the arithmetic sum of the individual moment applied to each jaw.

Finger length
is measured from the reference surface as the distance P in direction to the main axis.

Repeat accuracy
is defined as a distribution of the end Position for 100 consecutive strokes.

Workpiece weight
is calculated for force-fit gripping with a coefficient of static friction of 0.1 and a safety factor of 2 against workpiece slippage at acceleration due to gravity g. For form-fit or capture gripping, there are significantly higher permissible workpiece weights.

Closing and opening times
are movement times of the base jaws only, without application-specific gripper fingers. Valve switching times, hose fill times, or PLC reaction times are not included, and are to be considered when cycle times are calculated.

Operating principle
Wedge-hook kinematics

Housing material
Aluminum alloy, anodized

Base jaw material
Steel

Actuation
pneumatic, with filtered compressed air as per ISO 8573-1:2010 [7:4:4].

Warranty
24 months

Scope of delivery