TCU-P-200-3-OV
ID 324865
- Force Fd max.: 5000 N
Technical details
| 锁紧 | 无锁定 |
|---|---|
| 弹性体的硬度 [Shore] | 68.0 |
| 挠曲 X [°] | ± 1 |
| 挠曲 Y [°] | ± 2 |
| 挠曲 Z [°] | ± 1.5 |
| 重量 [kg] | 1.0 |
| 最低环境温度 [°C] | -10.0 |
| 最高环境温度 [°C] | 90.0 |
| 最大力 Fd [N] | 5000.0 |
| 直接连接至* | PGN-plus 200 |
| 长度 X [mm] | 100.0 |
| 宽度 Y [mm] | 154.0 |
| 力矩 Mx max. [Nm] | 200.0 |
| 力矩 My max. [Nm] | 80.0 |
| 力矩 Mz max. [Nm] | 140.0 |
Dimensions and maximum loads
Deflection
负荷图
最大偏离
Dimensions and maximum loads
The forces and torques are maximum values when unlocked and may occur simultaneously. When locked, only the loads caused by the weight and acceleration are permissible.
Deflection
Deflection (fa) dependent upon the length (L) to the center of mass
负荷图
- X-axis:
- 最大距离
- Y-axis:
- 最大搬运重量
最大偏离
取决于至质心长度(L)的挠曲(fa)
General notes about the series
Harsh environmental conditions
Please note that use under harsh environmental conditions (e.g. in the coolant area, cast and grinding dust) can considerably reduce the service life of the units, and we will not take over any warranty. However, in many cases we can find a solution. Please contact us for assistance.
Handling weight
is the weight of the total load attached to the flange. When designing, the permissible forces and moments have to be paid attention to. Please note that exceeding the recommended handling weight will shorten the lifespan.
Monitoring
by magnetic switch
Actuation
pneumatic, with filtered compressed air as per ISO 8573-1:2010 [7:4:4].
Material
Elastomer material
Housing
Aluminum alloy
Scope of delivery
Robot-side mounting screws
Warranty